basic setting 78 LP EGR data
meerschm

basic setting 78 LP EGR data

graph of data points gathered with BCDS basic settings 78, which increases idle and checks pressure across the LP egr filter. value over 100 mbar at temps around 200c likely to cause P0401 error due to cracked DPF